OPERATING AND MAINTENANCE MANUAL FOR
ELECTRIC STAINLESS STEEL HEATER
FOR DEIONIZED (DI) WATER
ELECTRIC HEATER COMPANY
BASE MODEL “ D ”
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - FOR DEIONIZED (DI) WATER

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMP

Página 2

10 Outlet to floor drain Install into provided tapping Manual Release Lever

Página 3

11THERMOSTAT SETTING (BULB AND CAPILLARY IMMERSION TYPE) The bulb and capillary type thermostat is immersed in a Type 316L stainless steel well in

Página 4

12 SECTION III - SCHEDULED MAINTENANCE AND OPERATION WARNING / CAUTION Before performing any maintenance procedure, make certain power supply is

Página 5 - CONSTRUCTION

13ANNUAL INSPECTION 1. Flush tank as follows a. Shut off power supply. b. Close valve on hot water outlet piping. c. Open valve on drain pipi

Página 6

14 SECTION IV – TROUBLESHOOTING Symptom Probable Cause Corrective Action / Remedy Circuit breaker tripped at source. Reset circuit breaker. Blow

Página 7

15Faulty thermostat. Check thermostat adjustment. Monitor thermostat as described in Section III, Quarterly Inspection. Replace if necessary. Heat

Página 8

16 SECTION V - SERVICING & REPLACEMENT OF PARTS WARNING / CAUTION Before servicing or replacing any part make sure to turn the power supply

Página 9 - SECTION II – INSTALLATION

17IMMERSION TEMPERATURE HIGH LIMIT CUT-OFF 1. Disconnect power from unit. 2. Remove access cover. 3. Remove high limit cover screw and cover.

Página 10

18 HEATING ELEMENT 1. Disconnect power from unit. 2. Shut off incoming water supply. 3. Attach hose to drain connection. 4. Lift manual release

Página 12 - WARNING / CAUTION

2 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203) 378-3593 INTERNET: http://www.hubbe

Página 13

20 IMMERSION THERMOSTAT 1. Disconnect power from unit. 2. Remove access cover and locate thermostat. 3. Remove high limit cover screw and cover.

Página 14 - SECTION IV – TROUBLESHOOTING

21MAGNETIC CONTACTOR 1. Disconnect power from unit. 2. Disconnect line and load wires to contactor. 3. Disconnect two (2) 14 gauge control circu

Página 15

22 RELIEF VALVE 1. Disconnect power from unit. 2. Shut off incoming water supply. 3. Lift test lever on relief valve to relieve pressure in tank.

Página 16

23SECTION VI – MISCELLANEOUS CHARTS AND FORMULAS ELEMENT CHART Power (kW) Resistance (Ohms) Element Part # 208V 240V 480VImmersion Length

Página 17

24 TORQUE VALUES BOLT SIZE 18-8 S/S IN.-LBS. BRASS IN.-LBS. SILICONBRONZE IN.-LBS. ALUMINUM2024-T4 IN.-LBS. 316 S/S IN.-LBS. MONEL IN.-LBS. 4-40 5.

Página 18

3 TABLE OF CONTENTS SECTION TITLE PAGE #

Página 20

5SECTION I - GENERAL DESCRIPTION AND CONSTRUCTION GENERAL DESCRIPTION This booklet describes an electric heater designed specifically for use in d

Página 21

6 CONTROL THERMOSTAT The water heater is supplied with a single stage immersion thermostatic switch that is installed and wired at the factory. The

Página 22

7 OUTER SHELL AND INSULATION The tank is encapsulated in 2-inches of high-density fiberglass insulation. The protective shell is constructed of ga

Página 23

8 Individually Fused Elements To prevent the possibility of damage to control circuits and other elements in case of electrical overloads, fuses may

Página 24

9SECTION II – INSTALLATION WARNING / CAUTION DO NOT TURN ON THE ELECTRIC POWER SUPPLY to this equipment until heater is completely filled with w